Add to Favorites
Share

Digital Differential Pressure Sensor with 4-20 Ma Hart Protocol

  • Description
Product Detail

    Digital Differential Pressure Sensor with 4-20 Ma Hart Protocol    

    Production Introduction:

    Model:QP-86D differential pressure sensor

    QP-86D.jpg

    Dimensions :( unit: mm)

    QP-86D dimension.png


    Span:

    Range   code

    Range

    Measure   span

    MIN

    MAX

    4

    0.374KPa

    37.4KPa

    -37.4~37.4KPa

    5

    1.868KPa

    186.8KPa

    -186.8~186.8KPa

    6

    6.9KPa

    690KPa

    -690~609KPa

    7

    20.68KPa

    2068KPa

    -690~609KPa

     

    Output:

    Analog output: two wire 4~20mADC

    Digital output: two wire 4~20mADC and variable digital signal in accordance with HART AGREEMENT.

    Power: supply voltage 12.5~45VDC

    Limit load: Max load resistor Rmax in loop decided by the supply voltage, see the below drawing. HART AGREEMENY require the load resistor not less than 250 O, not more than 600O

    Communication distance: Max. 1.5km, multi-address communication can connect 15 smart transmitters max.

    Output display: 4 digital display, 5 digit LCD display, pointer type.

    Marking: ExiaII CT5; explosion-proof isolation type

    Zero offset: can positive offset or negative offset, but can not overstep the utmost value

    Temperature: environment temperature-40~85? (When choose LCD:-20~70?)

    Medium temperature:-40~104?

    Static pressure and one side overload: 3.45Kpa(Absolute)   31.2MPa(Gauge)

    Relative humidity:5 ~98%RH

    Startup time: less than 5 sec.

    Capability change: less than 4px3

    Damp adjust: 0.20~25sec.

    Malfunction alarming: If appear malfunction, automatism diagnose function will out 3.9 or 21.0mA

    Protection: To avoid the datas are modified random, can utilize

    Software or protect switch lock the memory data

    Reference condition: zero is the lower limit and not offset, temperature 25?, Atmospheric pressure, 24VDC power, silicon oil, diaphragm 316L, data adjust range the same as the up and lower limit of the range

    Accuracy: ±0.1%, adjust range=0.1URL

    ±[0.05+(0.005URL/span)]%, adjust range 0.025URL~0.1UPL

    ±[0.01+(0.006URL/span)]%, adjust range 0.01URL~0.025URLNote: accuracy have include the influence of linearlity, hysteresis and repeatability

    Stability: ±0.1%URL/year

    Tem.influence: ±(0.05%URL+0.15%span)/20?

    Static pressure influence: ±zero error 0.1URL/6.9Mpa

    Libration effect: withstand frequency 200Hz at any direction, arouse error ±0.05%URL

    Power influence: 0.005%/V

    Load influence: no load influence.

    Install position influence: about 250Pa zero offset, can be eliminate via calibration, no range influence.

    RF interference: drift is ±0.1%span in the condition of 30-1000MHz frequency and the most field intensity 10V/m